- What is the difference between model 0700 and model 01500N1?
- Is Thermofocus accurate?
- What are Thermofocus' advantages if compared to other thermometers?
- How does Thermofocus work?
- Is the temperature visualized with Thermofocus the same as the one taken with other thermometers and in other parts of the body?
- Sometimes the temperature that I read on my Thermofocus' display is too low, if compared to the one normally taken. Why?
- What happens if the red lights are unintentionally directed to the eyes?
- After the first measurement, how long do I have to wait to take another one, if necessary?
- Can Thermofocus be used to take the body temperature in people of any age?
- Are there situations when Thermofocus must not be used? (for instance on a sweaty forehead?)
- Why does model 01500N1 never turn off?
- Being always on, does model 01500N1 consume a lot?
- Can I change the setting from oral to rectal?
- Can I change the setting from centigrade to Fahrenheit?
- Can I check if the thermometer is correctly calibrated?
- Do I have to do the calibration check every time that I take a measurement?
- Taking furthest measurements, my Thermofocus visualizes different temperatures (more than 0,2°C difference). How is it possible?


What is the difference between model 0700 and model 01500N1?
Model 0700 just has one button “on” ”, that is used to take both the body temperature on the forehead (directly), and the objects' temperature (subtracting a certain value).
In model 01500N1, instead, the presence of two buttons allows you to measure directly both the body temperature on the forehead (button “face” ) both the one of the objects or of other body parts (button “home” ). Moreover, while model 0700 after around twenty seconds of non-use automatically turns off, model 01500N1 goes stand-by, visualizing the room temperature and it does never turn off.

 
Is Thermofocus accurate?
Yes, Thermofocus is accurate within a margin for error of +/-0,2°C (for body temperatures between 36 and 39°C) and of +/-0,3°C (for body temperatures under 36 and above 39°C) fixed by the standard ASTM E1956-98. To have always the greatest precision, it is important to read the instructions carefully and to respect the conditions of use
 
What are Thermofocus' advantages if compared to other thermometers?
Thermofocus is a real vanguard thermometer because it is easy to be used, it is not invasive, it is reliable, safe, very fast and absolutely hygienic. There are no breaking risks as it is with a mercury thermometer during rectal measurements. Moreover, unlike other thermometers, Thermofocus does never get in contact with the patient, so there is no need of disinfecting it and it does not need any hygienic protection.
 
How does Thermofocus work?
Thermofocus collects the infrared emissions coming from any body and, specifically, from the human beings' forehead. When the button is released, Thermofocus does, in a few hundredth of a second, a series of more than a 100 records that are amplified and elaborated by its sophisticated microprocessor, together with the room temperature's value coming from a thermocouple probe incorporated inside the sensor.
The data are compared to the parameters in the memory and the results of these processings is the temperature visualized on the display.

 
Is the temperature visualized with Thermofocus the same as the one taken with other thermometers and in other parts of the body?
The temperature taken with Thermofocus is normally very similar, but not necessarily equal, to the temperature taken with other thermometers in other parts of the body.
Following the dissipation of heat that the non-protected parts of the body undergo, the normal temperature that can be taken on a person's forehead is usually lower than the one of other covered parts. For this reason, Thermofocus' internal software automatically applies a correction to give a value that is approximately comparable to the oral temperature.
This correction is statistically calculated on a series of around ten thousand measurements. But, as the differences between the temperatures in the different areas of the body (axillary, oral, rectal, auricolar) are not stable, but vary from person to person, so do the differences between the temperatures on the forehead and the one in other areas of the body, which are peculiar of every person. It is thus normal that the two temperatures can differ of 5 or 6 tenth or sometimes even more than this.

In any case, to better assess possible feverish states, it is convenient to know the temperature of every single family member, when in ideal health conditions and in the various moments of the day, to take it as a reference in case of fever. For example, a subject with a particularly low temperature in good health conditions will have a lower fever's threshold if compared to a subject who normally has a high temperature.

 
Sometimes the temperature that I read on my Thermofocus' display is too low, if compared to the one normally taken. Why?
- The lens could be dirty: the presence of dust or little hair, filters the passage of infrared emissions coming from the human body and so Thermofocus can take a temperature which is lower than the real one. It is necessary to clean it gently with a cotton applicator dampened with alcohol.
- The forehead could be sweaty, or the measurement is being taken on areas covered by hair (the navel in adult men or the armpit). In these cases Thermofocus is not able to take reliable measurements. In case of children with a sweaty forehead, with the model 01500N1, through the home button, it is possible to take the temperature also on the navel or on the armpit. Make sure of not undressing the child in advance, but to move the clothes for the strictly necessary time and immediately before the measurement, to avoid the belly's (or the armpit's) heat dispersion.

 
What happens if the red lights are unintentionally directed to the eyes?
Nothing happens, the tracking lights are totally harmless. THEY ARE NOT LASER BEAMS!
 
After the first measurement, how long do I have to wait to take another one, if necessary?
With Thermofocus it is possible to take another measurement immediately
 

Can Thermofocus be used to take the body temperature in people of any age?
For the comfort of its use, its non-invasive methods and its quick measurements, Thermofocus has been designed for children, but adults can also use it. However, it is important to bear in mind that sometimes in elderly people, the temperature taken with Thermofocus could be lower than the real one, above all in elderly people and with a high rugosity of the forehead

 
Are there situations when Thermofocus must not be used? (for instance on a sweaty forehead?)
Thermofocus is not able to take reliable measurements if the forehead is sweaty or if the area where the measurement is taken, for example the navel in adult men or the armpit (with model 01500N1), is covered with hair.
 
Why does model 01500N1 never turn off?
Model 01500N1 goes stand-by after 30 seconds of non-use, always visualizing the room temperature. Besides the comfort of having a clinical thermometer that also is a room thermometer, its main purpose is to check that the thermometer's temperature constantly corresponds to the real room temperature, to take measurements in conditions of complete adaptation of the same thermometer. It is a very useful function, for example, for the doctors who visit their patients: as a matter of fact, coming from outside the thermometer is at a temperature normally different from the internal one of the house; in this way, it is possible to check when the thermometer has adapted that is, when it is possible to take another valid measurement.
 
Being always on, does model 01500N1 consume a lot?
When model 01500N1 goes stand-by, it is not completely active, but it goes in the same pause position, with very low consumptions, as the ones of a cell phone when there are no conversations in process or of a non working TV, but ready to be turned on through the remote control. Its autonomy with new batteries is around 3 years of 10 thousands measurements.
 
Can I change the setting from oral to rectal?
Your thermometer has come out of the manufactory with the ORAL setting, but if you like you can change the setting to RECTAL (this operation is not possible with model 0700).
With the stand-by thermometer, press the “face” button for around 8 seconds, until RECTAL appears (or ORAL in case RECTAL has already been set). Release the button. After a few seconds, the thermometer will be ready to take a measurement with the new setting. When the thermometer is set on RECTAL, the visualized temperature is 0,6°C more than the one visualized with the ORAL setting.

 
Can I change the setting from centigrade to Fahrenheit?
Your thermometer has come out of the manufactory with a °C or a °F setting according to the destination country, but, if necessary, you can change the reference.
When the thermometers is off (mod. 0700) or stand-by (mod. 01500N1), press the button
“on” or “home” for about 8 seconds, until the symbol °F appears (or °C if the thermometer was set on °F). Release the button. After a few seconds, the thermometer will be ready to take a measurement with the new setting.

 
Can I check if the thermometer is correctly calibrated?
It is possible to check the correct room reference doing a calibration check as indicated on the directions manual. This operation is not possible with model 0700.
To do this check it is very important that the thermometer is very well adapted. It is essential to keep it in an environment with stable and constant temperature, between 20 and 40°C, far from blasts of air or sources of heat and do the operation without taking the thermometer in your hand, but leaving it on a shelf.
Without leaving the cap, when the thermometer is in a pause position, press the two buttons “face” and “home” simultaneously: CAL will appear and after a few seconds the led will flash, finalizing the check. If just after YES and READY will appear, in case with a figure, it means that the thermometer is correctly calibrated. If E7 appears, make sure to have strictly respected the procedure, and if necessary do a second test. If you obtain the same result, contact us at the following e-mail address: info@tecnimed.it.

 
Do I have to do the calibration check every time that I take a measurement?
Absolutely not. The calibration test has to be done only when you have doubts on the measurements' reliability, (after making sure of strictly respecting Thermofocus' use conditions), or if the instrument has been bumped.
 
Taking furthest measurements, my Thermofocus visualizes different temperatures (more than 0,2°C difference). How is it possible?
- May be the thermometer is not always directed on the same point in the center of the forehead or it has been moved before the lights end to flash: make sure of keeping the thermometer perpendicular to the center of the forehead and, after having released the button, keep it still until the lights flash. If you position the thermometer in different points of the forehead, you will surely get variable measurements.
- The thermometer was in a room with a temperature that was different from the one where the measurement is taken. Wait fifteen-twenty minutes before taking any other measurement so that the can get adapted.